Skip to main content

HP OMi Plugin

You can configure the HP OMi Plugin integration to post data to Moogsoft Onprem when an event occurs in HP OMi. The integration requires you to configure external event processing in HP OMi.

The HP OMi Plugin does not require authentication. The integration listens without requiring password information.

If you are configuring a LAM-based integration, refer to the LAM and Integration Reference to see the integration's default properties.

When you use the integrations UI, you can only configure the visible properties. If you want to implement a more complex HP OMi LAM with custom settings, see Configure the HP OMi Plugin LAM.

See the HP OMi documentation for details on HP OMi components.

Before You Begin

The HP OMi Plugin integration has been validated with HP OMi v10.1. Before you start to set up your integration, ensure you have met the following requirements:

  • You have the URL for your HP OMi workspace.

  • You have credentials to connect to HP OMi with permissions to configure External Event Processing.

  • HP OMi can make requests to external endpoints over port 443. This is the default.

Configure the HP OMi Plugin Integration

Configure the HP OMi Plugin integration in Moogsoft Onprem as follows:

  1. Navigate to the Integrations tab.

  2. Click HP OMi Plugin in the Monitoring section.

  3. Provide a unique integration names. You can use the default name or customize the name according to your requirements.

Configure HP OMi

To configure HP OMi to work with the integration, create a connected server to Moogsoft Onprem. Then configure the server as the target server for an event forwarding rule. See the HP OMi documentation for details.

  1. Log into HP OMi and create a Connected Server with type External Event Processing as follows:

    Step

    Field

    Value

    General

    HP OMi plugin integration URL

    <your HP OMi Plugin integration URL, protocol omitted>

    example1.moogsoft.com/integrations/api/v1/events/hpomiplugin1 

    Name

    AIOps_Server

    Server Properties

    Fully Qualified Domain Name

    <the host name of your Moogsoft Onprem server>

    example2.moogsoft.com

    CI Type

    Management System. Any CI Type will work.

    Integration Type

    Call Script Adaptor

    Selected

    Script Display Name

    AIOps_Push_Adaptor. Use Manage Scripts to create a new script.

    Script Description

    Adaptor to send alerts to HP OMi Plugin integration

    Script

    For a LAM-based integration: Contents of CHpomiPushAdapter

    For a UI-based integration: Contents of CHpomiPushAdapterUI

    Outgoing Connection

    Port

    <Port for HP OMi Plugin integration>

    48015 (by default)

    NOTE: The port is only used by LAM integrations.

    Use Secure HTTP

    Selected. Retrieve the certificate from the server or supply the certificate files.

  2. Create an event forwarding rule or edit an existing rule to target the server:

    • Select the "Moogsoft Onprem Server" as the Target Server for the rule.

    • Set Forwarding Type to Notify and Update.

When an event triggers the rule, HP OMi forwards the event to Moogsoft Onprem.